Can I use 15 amp GFCI in the bathroom? (2022)

Wiring in a home is always delicate and each place that you will do some wiring needs some better electrical knowledge. But in whatever place that you will have wired, even in a bathroom, it has to follow the electrical follow-up of the code of requirements that are set forth by the local building’s office. What has come on these is that these changes have always changed and become better and more exact as compared to other years. This is because electrical demands are increasing with time and you always need to be safer at all times.

Most homes have their electrical codes based on the NEC, that’s is the National Electrical Code. This is a document that was assembled by a committee of electricians and the best building professionals that are aimed at ensuring there is maximum safety when it comes to electrical installations. Always consult your local code as that will always supersede what NEC will provide.

Some of the homeowners will be stuck as to whether they can install the Ground-Fault Circuit Interrupters (GFCI) on a dedicated circuit. This is because there is already existing wiring and if it does not meet the current code requirements, then you will be out suffering on the installation. The new requirements that have been made will ensure that new construction or any remodeling jobs where the bathroom footprint and wiring need to be expanded are always done in a qualified manner.

This is what happens when you get a professional electrician doing some work on your bathroom, then he or she should be aware of what kind of connections are there. At the same time, he or she can tell which kind of upgrades will be necessary for upgrading and when the existing wires need to remain just the way they are. Some people might decide to do the wiring themselves, which is a bad idea about you can try it anyway. What you will need to do is to first consult your local building inspection office so that you are guided on what is to be done.

Does a bathroom GFCI need to be on a dedicated circuit?

Sale

Faith 15A GFCI Outlet, Non-Tamper-Resistant GFI Duplex Receptacle with LED Indicator, Self-Test...

  • Specifications: Electrical rating 15A/125V/1875W. Meets or exceeds UL943 2015 standards. Compliant with National Electric Code (NEC) requirements. ETL Listed.
  • Slim GFCI Outlet: New slim, modern design for easier and quicker installation in shallow electrical boxes.
  • GFI Outlets: Provides protection from electrical shocks that might occur from faulty appliances in damp locations. Device detects and trips on ground faults within 1/40 of a second

Last update on 2021-11-13 / Affiliate links / Images from Amazon Product Advertising API

This is one simple answer if you will have to understand how it is done and connected. What you need to know first is the availability of power in the switch box. In some older versions, no neutral wire is put at the switch, hence there is no power for the receptacle at the box. You can go ahead and add your GFCI to a dedicated circuit with the use of the 20-amp receptacle circuit. You need an expert to ensure that things and connections are done well.

The number of circuits that are in the bathroom.

A bathroom might look like a small space that only need a small space that only needs a circuit extension so that it works in a better manner than an adjoining room. But something that needs to know is that the NEC will require that every room just uses at least 2 dedicated circuits for each of the bathrooms. Here is what you need to know about circuits,

  • You are advised to use a 20-amp receptacle kind of circuit to handle the plug-in appliances. With the receptacle, they all need to be AFCI and GFCI protected. You can either use circuit breakers or use individual receptacles that will offer you the AFCI and GFCI protection abilities.
  • Don’t mix things up. Ensure that light fixtures together with wall switches should be placed on a different circuit. You can decide to use the 15-amp circuit but the 20-amp circuit works best especially when you realize that you have a heat lamp included in your connections or your bathroom.
  • If you have a whirlpool tub, you also need a separate circuit. This also applies to the availability of any large item that you might feel the need to use in the bathroom.

With circuit breakers, it is good that their dedications just remain serving the bathrooms and not mixing them with other rooms. It all depends on how your local jurisdiction has its laws put. Always be there to consult them or even find out how that should be done, in case you need to have the rooms interconnected.

Lighting

There is always one able to have at least one lighting in the bedroom. This fixture can be wall-mounted just above the mirror or by using a pair of wall scones to mount it on the sides of the mirror. You cannot evade any kind of lighting in a bedroom because it is one of the prominent items that you will just need to have. Don’t get mesmerized when you find 3 lighting sources because they will all ensure that your bathroom is one of a kind. You can have ceiling lighting, and vanity lighting well installed, and then the 3rd light integrated into the shower or vent fan. If the light is put in the shower stall, ensure to use a waterproof lens so that your hands and bulb are well protected.

(Video) BATHROOM WITHOUT GFCI !!! Electrician mistake?

What kind of outlet receptacles are you required to have?

ANKO GFCI Outlet 20 Amp, UL Listed, Tamper-Resistant, Weather Resistant Receptacle Indoor or Outdoor...

  • GFCI Outlet - Constructed with premium high-impact resistant thermoplastic materials and rational structure design, ensures superior strength and durability. it a single gang GFCI electrical box that supports a standard duplex, grounded receptacle; Safe electrical GFCI outlet tester with TEST and RESET buttons and LED Indicator is designed to meet local and national electrical codes.
  • Safty - The ANKO GFCI USB Outlet meets UL-Listed YGB-095WR, 20 Amp, 125 Volt, 60HZ. Tamper Resistant Receptacle prevents young children from inserting unwanted objects into the outlets. For an added layer of protection, the GFCI regularly conducts an automatic internal test to confirm that it can respond to a ground fault, provides continuous ground fault protection.
  • Weather Resistant - Constructed with advanced UV stabilized engineering to provide superior corrosion, temperature, and UV resistance, preventing discoloration and aging, ideal for outdoor & indoor use. Ground fault circuit interrupter GFCI outlets are required in kitchens and bathrooms and within 25 feet of heating, air conditioning and refrigeration equipment to prevent electrical shock in areas subject to moisture.

Last update on 2021-11-13 / Affiliate links / Images from Amazon Product Advertising API

(Video) How to Wire a GFCI Outlet - What's Line vs Load? - Electrical Wiring 101

An outlet receptacle that can be used in a bathroom should be one that is GFCI-protected. But it also needs to be served by the 20-amp circuit. That’s is just the minimum that you can use but most times, bathrooms can have up to 2 receptacles. With others having up to 4 or even 5.

Receptacles are not just bought because they are out there, you will need to have the best of the best at all. You also need to ensure that you have the correct kind of measurements in place. You need to ensure that the receptacle is at least 6 feet away from the edge of the bathtub. When in the shower, it should be at least 1 foot away from the sink.

One thing that I have to remind you is to avoid placing replaceable at any one point at the center of the sink. This is because chords and hairdryers might hang down into the basin. Depending on the size of the bathroom, you will find that it will be necessary to add a general outlet near the door so that you can plug in a vacuum cleaner when you will need to use it. Some have incorporated a table into their bathroom. That will be a great place that they can use to place a socket.

Installation of the exhaust fan.

You can also go ahead and have a fan installed in your bathroom. The electric fan is vital as it will allow better air circulation and removal of the moist air from the bathroom. The installation of fans should be done right because they are calculated by the use of CFM, cubic feet per minute. Knowing how it works will allow you to decide where you will need to have it installed better with the circuits.

Can I use 15 amp GFCI in the bathroom? (3)

6,941 Reviews

(Video) Removing and Replacing regular outlet with GFCI outlet

Broan-NuTone 688 Ceiling and Wall Ventilation, 50 CFM 4.0 Sones, White Bath Fan

  • VERSATILE FAN: Ventilation fan helps eliminate humidity, tobacco smoke, and cooking odors. Install the compact fan between ceiling joists or wall studs - wherever it's needed most!
  • EFFICIENT: Operates on 50 CFM and has a 4. 0 Sone rating to ensure a peaceful surrounding when in operation
  • EASY INSTALLATION: Torsion springs grille mounting - no tools necessary for a quick and easy installation

Last update on 2022-08-03 / Affiliate links / Images from Amazon Product Advertising API

Any type of connection that should be done in a bathroom should always be done carefully at all times. This is because this is a place that will be having water and if something goes wrong, then you can be sure that there will be some problems that you will encounter.

You may also like:

How to tighten moen bathroom faucet handle?

Can you use toilet bowl cleaner on other surfaces?

How to remove scratches from high gloss kitchen doors?

Is it safe to run a dehumidifier constantly all the time?

(Video) Shall I Use a 15A or a 20A Receptacle on a 20A Circuit? + 2020 NEC 210.21(B)(1) and 210.21(B)(3)

FAQs

Can you use a 15 amp GFCI in a bathroom? ›

The minimum requirement for outlet receptacles in a bathroom is one GFCI-protected receptacle served by a 20-amp circuit. This is a bare minimum, however, and most bathrooms will have at least two receptacles, and often as many of four or five.

How do you know if you need 15 or 20 amp GFCI? ›

How to check if you have 15amp or 20amp circuit in home - YouTube

Can I use a GFCI breaker instead of an outlet in a bathroom? ›

It's recommended that each bathroom has two or three GFCI protected outlets. The number of outlets you choose to protect is up to you, as long as you have at least one GFCI protected outlet in a bathroom. You can achieve shock protection with a GFCI circuit breaker in the electrical panel or by installing GFCI outlets.

Can bathrooms be 15 amp? ›

The Bottom Line. While older bathrooms were often served by one 15-amp circuit, a new or remodeled bathroom generally requires at least two circuits—a 15-amp or 20-amp general lighting circuit and a 20-amp outlet circuit. A third 20-amp circuit may be required to power the vent fan if it includes a heat lamp.

What is the difference between a 15 amp and 20-amp GFCI? ›

There are different pin configurations for 15a and 20a receptacles. A 20a receptacle has one slot that is turned sideways or T shaped to allow a 20amp plug to be used. A 15amp receptacle won't overload the circuit. Only 15a devices will be allowed to be plugged in.

Can bathroom GFCI and lights on same circuit? ›

GFCI Protection on Both Lights & Receptacles in Bathroom? - YouTube

What happens if you put a 20-amp GFCI outlet on a 15 amp circuit? ›

I'll start by acknowledging that I know this violates NEC. As I understand it, the reason that a 20 amp outlet can't be connected to a 15 amp circuit is that someone could potentially connect a 20 amp device, overload the circuit, and cause a fire.

Can I replace a 20-amp GFCI with a 15 amp GFCI? ›

According to National Electrical Code, only a 15-amp or 20-amp electrical receptacle can be installed to a 20-amp circuit. A 15-amp receptacle may also be installed on a 15-amp circuit. However, a 20-amp GFCI outlet may not be installed to a 15-amp circuit.

Can you replace a 15 amp receptacle with 20-amp? ›

For instance, it is crucial that the amperage of an outlet doesn't exceed the amperage of the circuit it uses. As a result, both 15 amp and 20 amp electrical sockets can be installed to a 20 amp circuit, yet only 15 amp receptacles should be used for 15 amp circuits.

Why does my bathroom GFCI keep tripping? ›

If your insulation is worn out, old, or damaged, it could cause your GFCI to trip. The insulation is in the wall is meant to help prevent such leaks from occurring. So if your insulation is worn, this can cause more leaks. Sometimes having too much equipment or appliances plugged in can also cause your GFCI to trip.

What is the difference between a GFI and a GFCI? ›

Ground fault circuit interrupters (GFCI) and ground fault interrupters (GFI) are the exact same device under slightly different names. Though GFCI is more commonly used than GFI, the terms are interchangeable.

Does every outlet in a bathroom need to be GFCI? ›

Where Should GFCI Outlets Be Installed? Bathrooms – All bathroom receptacles should have GFCI outlets installed. Garages & Sheds – Any area inside or outside of the house that is not considered a "habitable" room should include GFCI outlets. This includes garages, sheds, and any other work/storage areas.

How many GFCI do I need in my bathroom? ›

Electricity and water don't mix

According to the National Electric Code (NEC), it requires a minimum of one GFCI-protected outlet per bathroom. The national recommendation is more than one, like two or three. You get to decide how many outlets you want to protect but have to have a minimum of one in your bathroom.

How close can a GFCI be to a bathtub? ›

Receptacles shall not be installed within a zone measured 900 mm (3 ft) horizontally and 2.5 m (8 ft) vertically from the top of the bathtub rim or shower stall threshold.

Can I use 20-amp GFCI on 15 amp circuit? ›

According to National Electrical Code, only a 15-amp or 20-amp electrical receptacle can be installed to a 20-amp circuit. A 15-amp receptacle may also be installed on a 15-amp circuit. However, a 20-amp GFCI outlet may not be installed to a 15-amp circuit.

Does the GFCI for bathroom have to be in a dedicated circuit? ›

Bathroom Electrical Code Requires AFCI and GFCI Protection

Ground fault circuit interrupters (GFCIs) have long been required in bathrooms, but since 2014, the NEC has required arc-fault circuit interrupter (AFCI) protection in every lighting and outlet branch circuit in the house, which includes the bathroom.

Does a bathroom GFCI need to be on its own circuit? ›

Bathroom GFCI Outlet Circuit

The bathroom GFI receptacles circuit should be dedicated for the bathrooms alone. It would be best to extend the bedroom outlet circuit to the location of the TV or to install a new circuit to the TV location.

How many outlets can be on a 15 amp circuit? ›

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.

Videos

1. DIY How To Install Bathroom GFCI Outlets and Light Switch
(jeffostroff)
2. How to install or replace a GFCI Outlet
(DIY Creators)
3. I have a GFCI in bathroom. Eagle class A GFCI-20A-2P (15A
(JustAnswer-Q&A)
4. How To Replace A GFCI Outlet / Step By Step
(The Handyman Journey)
5. Do all outlets in a bathroom need to be GFCI?
(Ask About CELEBS)
6. How To Install A 15amp GFCI Outlet
(LoserUpInACamera)

Top Articles

Latest Posts

Article information

Author: Wyatt Volkman LLD

Last Updated: 12/07/2022

Views: 6093

Rating: 4.6 / 5 (46 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Wyatt Volkman LLD

Birthday: 1992-02-16

Address: Suite 851 78549 Lubowitz Well, Wardside, TX 98080-8615

Phone: +67618977178100

Job: Manufacturing Director

Hobby: Running, Mountaineering, Inline skating, Writing, Baton twirling, Computer programming, Stone skipping

Introduction: My name is Wyatt Volkman LLD, I am a handsome, rich, comfortable, lively, zealous, graceful, gifted person who loves writing and wants to share my knowledge and understanding with you.